Current Limiting Fuse Cutout for 33kv-36kv High Voltage Applications

Product Details
Customization: Available
Breaking Capacity: High
Type: Current Fuse
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Self-branded
The supplier has 1 Self-brands, check the Audit Report for more information
to see all verified strength labels (26)
  • Current Limiting Fuse Cutout for 33kv-36kv High Voltage Applications
  • Current Limiting Fuse Cutout for 33kv-36kv High Voltage Applications
  • Current Limiting Fuse Cutout for 33kv-36kv High Voltage Applications
Find Similar Products
  • Overview
  • Product Description
  • Technical Specification
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
HYNC1WF-36
Usage
High Voltage
Shape
Dropout
Fusing Speed
K
Fusing Device
Fuse Element
Rated Voltage
33kv-36kv
Creepage
1080mm
Lightning Impulse Voltage
170kv
Power Frequency Voltage
70kv
Material
Polymer
Transport Package
Carton&Pallet or Wooden Case
Specification
100A/200A
Trademark
YN
Origin
China
HS Code
8535100000
Production Capacity
250000PCS/Year

Product Description

Product Description
Current Limiting Fuse Cutout for 33kv-36kv High Voltage Applications
Current Limiting Fuse Cutout for 33kv-36kv High Voltage Applications
Current Limiting Fuse Cutout for 33kv-36kv High Voltage Applications

Powerful High Voltage Current Limiting Polymer Drop-Out Fuse Cutout, expertly designed as Load Break Fuse for 33kv-36kv with an impressive Creepage distance of 1080mm.

Experience unparalleled protection with our drop-out fuse cutout and load switching fuse cutout, meticulously crafted for outdoor high-voltage protective applications. These devices seamlessly integrate with distribution transformers or lines, offering robust defense against short circuits, overloads, and efficient current on/off loading. The sophisticated design includes insulated supports and a durable fuse tube with static contacts securely affixed on either side, while the moving contact fits seamlessly at the tube's ends. Inside, the arc-extinguishing tube-constructed from high-performance phenolic compound paper or epoxy glass-ensures reliability. Load switching fuse cutouts feature resilient auxiliary contacts and an arc-extinguishing enclosure for precise on-off operations.
In regular operation, the fuse link maintains a secure position within the fuse tube. However, should a system fault arise, the rapid response of fault current promptly melts the fuse, inducing an electric arc. This action heats the arc-extinguishing tube, producing high-pressure gas that expels the arc powerfully along the tube. The release of tension in the moving contact triggers the mechanism, allowing the fuse tube to drop out and transition to an open position. For on-load disconnection, operators use an insulating bar to deftly manipulate the moving contact. Initially, the main contact and auxiliary static contact remain engaged, but upon continued pulling, the auxiliary contact separates, generating an electric arc. This arc, expertly extended within the arc-extinguishing enclosure gap, is efficiently extinguished as gas is explosively released at current zero.


 
Technical Specification

Current Limiting Fuse Cutout for 33kv-36kv High Voltage Applications
 
Type
Rated
voltage (KV)
Rated
current
(A)
Breaking
current
(A)
Impulse
voltage
(BIL)
Power
frequency withstand voltage
Leakage distance
(MM)
HYNC1WF-36/100 33-36 100 8000 170 70 1080
HYNC1WF-36/200 33-36 200 10000 170 70 1080
Company Profile

Current Limiting Fuse Cutout for 33kv-36kv High Voltage Applications

Established in 2007 and strategically located in the heart of China's Electric Capital, Yueqing City, Yuanneng Power stands at the forefront of power infrastructure services. Specializing in generation, transmission, and distribution systems, our modern high-tech enterprise seamlessly integrates production, development, sales, and service. Our diverse product lineup includes polymer insulators, fuse cutouts, surge arresters, disconnect switches, and associated power fittings, demonstrating our robust industry presence.

Embracing globalization, Yuanneng adapts to diverse regional and market demands, adhering to esteemed standards such as IEC, ANSI, IEEE, and GB. Our products have earned accolades and certification from prestigious institutions including Xi'an High Voltage Apparatus Research Institute Co., Ltd (XIHARI), National Insulator & Lightning Arrester Quality Supervision Inspection Center, and State Grid Electric Power Science Academy Quality Inspection Test Center.

By leveraging the swift and convenient shipping capabilities of Ningbo and Shanghai Ports,
Yuanneng Power extends its reach to international markets, boasting an annual production capacity that includes 500,000 polymer insulators, 500,000 lightning arresters, 350,000 dropout fuse cutouts, and 250,000 disconnect switches. This expansive capacity underpins our competitive edge and steadfast support to our global clientele.

Guided by our core philosophy of 'Human-oriented, Credibility-based' development, Yuanneng Power eagerly anticipates the opportunity to collaborate with you. Together, let's connect electricity and unite the world.

Current Limiting Fuse Cutout for 33kv-36kv High Voltage ApplicationsCurrent Limiting Fuse Cutout for 33kv-36kv High Voltage ApplicationsCurrent Limiting Fuse Cutout for 33kv-36kv High Voltage ApplicationsCurrent Limiting Fuse Cutout for 33kv-36kv High Voltage ApplicationsCurrent Limiting Fuse Cutout for 33kv-36kv High Voltage ApplicationsCurrent Limiting Fuse Cutout for 33kv-36kv High Voltage ApplicationsCurrent Limiting Fuse Cutout for 33kv-36kv High Voltage Applications
FAQ
Current Limiting Fuse Cutout for 33kv-36kv High Voltage Applications
Q: Are you manufacturer or a trade company?
We are a true professional manufacturer more than 15 years in China.

Q: Where is your factory?
Our factory address is
Room 101, Building 2, No. 28, Binhainansan Road, Yueqing Economic Development Zone, Yueqing City, Wenzhou City, Zhejiang Province, China.

Q: Can I produce fuse cutouts according to my own requirements?
Surely, OEM & ODEM is welcome.

Q: May I get a fused cutout sample to check firstly?
Yes, the sample fee and courier fee need be paid by your esteem company, we will return cost back to you within your first order.

Q: How about sample time?
Normally, it can be ready in one week.

Q: What's your MOQ and delivery time?
For cutout, its MOQ should be 100pcs, delivery time is 25 days.

Q: Do you have type test report for ad drop out fuse cutout?
Yes, but consider test fee is very high, we make test on some models, welcome to contact to know details.

Q: What is your payment term?
Our payment term is T/T, L/C, if you have other idea, let us discuss.

Q: What is package for fuse cutout?
For porcelain and polymer fuse cutout, we will pack by carton+ pallet packing.

Q: What is standard of your cutouts?
IEC 60282-2, IEEE/ANSI C37.41, IEEE/ANSI C37.42

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now